FXC SERIES BENDING BEAM LOAD CELLS



FXC SERIES BENDING BEAM LOAD CELLS



Dimensions (mm)

Wiring Code
Colour
Function
SHIELD
BLACK
OUTPUT +
RED
INPUT +
BLUE
OUTPUT –
WHITE
INPUT –

Bending beam load cells for approved weighing, automatic systems, dosage.


CAPACITIES (kg): 10, 20, 50, 100, 200, 300, 500.


OIML R60.C3 precision class.


Stainless steel. IP68 protection.


Contents

MAIN FEATURES

  • C3 PRECISION CLASS
  • STAINLESS STEEL
  • IP68 PROTECTION
  • MAX. CAPACITIES FROM 10 TO 500 kg
  • SHIELDED CONNECTION CABLE
  • OIML CERTIFICATE AVAILABLE UPON REQUEST
  • TEST CERTIFICATE AVAILABLE UPON REQUEST

TECHNICAL FEATURES

  • Minimum load cell verification interval: Vmin = EMax / 10.000
  • Maximum number of verification intervals: nLC= 3000
  • Full Scale Output: 2mV/V +/- 0,1%
  • Combined error: 0,017% of Full Scale Output (F.S.)
  • Non-Repeatability: 0,015% F.S.
  • Temperature effect on zero: +/- 0,002% /°C
  • Temperature effect on full scale output: +/- 0,0012% /°C
  • Compensated Temperature Range: –10°C/+40°C
  • Operating Temperature Range: –20°C/+60°C
  • Creep error after 30 minutes +/- 0,016% F.S.
  • Maximum tolerated excitation voltage: 15 VDC
  • Input Resistance: 385 ± 20 Ohm
  • Output Resistance: 350 ± 5 Ohm
  • Insulation Resistance: > 5000 MOhm
  • Safe Overload: 200% F.S.
  • Ultimate Overload: 300% F.S.
  • Nominal displacement: < 0,4 mm
  • 4-wire shielded cable, 3m long, 4mm diameter.

ATEX VERSION

  • The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:

    ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga

    ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.

    The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).

  • IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.

DOWNLOAD

  • FXC.zip
  • LOAD CELLS_CE_170904.pdf
  • Available versions

    Code
    Max

    (kg)
    FXC10 10
    FXC20 20
    FXC50 50
    FXC100 100
    FXC200 200
    FXC300 300
    FXC500 500

    Assembly kits
    Code Description
    KFXDN Stainless steel kit for assembling 1 FXC/FXD cell up to 500kg. (Load cell not included)

    Options for ATEX version
    Code Description
    ZBA1S Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC.
    KZBA ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust.
    JB4QAI Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
    JB4QA ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
    EXCB6 (S6) Shielded, blue, 6×0,22mm² cable, for EX i (2GD) applications. €/m
    KMB4 Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts.
    CCATEX-1 Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT).
    DCATEXMECH DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications.
    DCATEXMB4 ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option).

    Connection cables
    Code Description
    LCCB Shielded 6×0,25 mm² cable (suitable for Ex zones). €/m
    LCCBM Shielded 4×0,34mmq cable for moving applications. €/m
    PRCB Protection sheathing for shielded cable. €/meter

    Junction Boxes
    Code Description
    JB4Q Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads.
    JB4Q Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads.
    JB4QI Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection degree, with 4 + 1 fairleads.
    JC4Q Equalisation board for up to 4 cells. With UL marked PCB, Terminal block, plastic box and labels (if expected).

    Available weight indicator/transmitter
    Code Description
    DGT1S Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program.
    DGT1 Weight transmitter for DIN bar. 5-key keypad, LED display, real time clock, alibi memory, and multifunction weighing programme.
    DGT4 Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme.
    DGTQ Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme.

    All the specifications and images can be subject to variations and upgrades without prior notice.

    Golden Lotus Bending Beam loadcell – under weighing.lotusscale.com cert., FXC SERIES BENDING BEAM LOAD CELLS Dini Argeo load cell by Diniargeo made in Italy (EU type).

    FXC SERIES BENDING BEAM LOAD CELLS Alu, stainless steel and alloy approved load cells, suitable for approved scales, or for weighing tanks and hoppers, with the aid of its accessories. Stainless steel compression load cells suitable for weighing, Digital version of compression load cells, 4000 divisions, Compression load cell for CE-M approved weighbridges, tanks, silos, etc. DiniArgeo Bending Beam loadcell Completely manufactured in steel, and fitted with selfaligned articulated joints, selfcentering plates and protection washer.

    * Golden Lotus Loadcell products post at Lotusscale.com is under sale right by “Golden Lotus M.E.C” we distribute DiniArgeo Scales and DiniArgeo Loadcells in Asia, Southern Vietnam and can advise product solutions, products and services. Feel free to contact us: hsv@hoasenvang.com.vn / or Call us: 8428 3511 7799 (GMT +7).