FXC SERIES BENDING BEAM LOAD CELLS |
|
|
|
Dimensions (mm)
Wiring Code
|
Colour |
Function
|
— |
SHIELD
|
BLACK |
OUTPUT +
|
RED |
INPUT +
|
BLUE |
OUTPUT –
|
WHITE |
INPUT –
|
|
|
|
|
DOWNLOAD
|
FXC.zip
|
LOAD CELLS_CE_170904.pdf
|
|
Available versions
Code |
Max
(kg) |
FXC10 |
10 |
FXC20 |
20 |
FXC50 |
50 |
FXC100 |
100 |
FXC200 |
200 |
FXC300 |
300 |
FXC500 |
500 |
Assembly kits
|
Code |
Description |
|
KFXDN a> |
Stainless steel kit for assembling 1 FXC/FXD cell up to 500kg. (Load cell not included) |
Options for ATEX version
|
Code |
Description |
|
ZBA1S a> |
Intrinsic protection three channel Zener barrier. Specific for connection to load cells, for mounting on DIN rail in a safe area, or in a hazardous-proof case. Marking: ATEX II (1) GD [Ex ia Ga] IIC [Ex ia Da] IIIC. |
|
KZBA a> |
ATEX ABS housing kit with Zener Barrier ZBA1S for load cells. For intrinsically safe weighing systems in an explosive zone. Dimensions 180x180x150mm.Can connect up to 4 Load Cell of 350 Ohm. Marking of housing + Zener Barrier ZBA1S: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +50°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +50°C) for dust. |
|
JB4QAI a> |
Stainless steel IP66, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). |
|
JB4QA |
ABS IP67, ATEX, equalisation box for up to 4 cells. 4 + 1 fairleads. Protection modes: ATEX II 2G Ex ib IIC T6 Gb for gases, ATEX II 2D Ex tb IIIC T115°C Db IP65 for dusts. Complete with manual and ATEX CE CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). |
|
EXCB6 |
(S6) Shielded, blue, 6×0,22mm² cable, for EX i (2GD) applications. €/m |
|
KMB4 a> |
Kit of 3 ATEX zener barriers for load cells, in an ABS box. For up to 4 load cells of 350 ohm, for intrinsic protection weighing systems in an hazardous area. Marking of the whole box with three Zener barriers: ATEX II 3(1)G Ex nA [ia Ga] IIC T4 Gc (-20°C ≤ Ta ≤ +40°C) for gas, ATEX II 3(1)D Ex tb [ia Da] IIIC T130°C Dc IP65 (-20°C ≤ Ta ≤ +40°C) for dusts. |
|
CCATEX-1 |
Optional ATEX version for single load cell. Categories: ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga and ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65. Complete with manual and ATEX EU CONFORMITY DECLARATIONS (available in EN, DE, FR and IT). |
|
DCATEXMECH |
DCATEXMECH: ATEX declaration for the PLATFORM / LOAD CELL ASSEMBLY KIT (for the load cells ATEX declaration see CCATEX-1 code). Option to be offered only if the platform is ordered without the indicator, if so, refer to the chosen weight indicator available certifications. |
|
DCATEXMB4 |
ATEX declaration of the whole for systems with zener barriers. Ex II 2GD IIC T6 T125°C X system, with relative label of whole system, for weight indicator connected to Dini Argeo zener barriers, connected to a mechanical structure with ATEX load cells (each cell must be certified with CCATEX option). |
Connection cables
|
Code |
Description |
|
LCCB a> |
Shielded 6×0,25 mm² cable (suitable for Ex zones). €/m |
|
LCCBM a> |
Shielded 4×0,34mmq cable for moving applications. €/m |
|
PRCB |
Protection sheathing for shielded cable. €/meter |
Junction Boxes
|
Code |
Description |
|
JB4Q a> |
Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads. |
|
JB4Q a> |
Equalisation box for connection with up to 4 load cells. ABS box, IP67 protection degree, with 4 + 1 fairleads. |
|
JB4QI a> |
Stainless steel equalisation box for connection with up to 4 load cells. IP65 protection degree, with 4 + 1 fairleads. |
|
JC4Q a> |
Equalisation board for up to 4 cells. With UL marked PCB, Terminal block, plastic box and labels (if expected). |
Available weight indicator/transmitter
|
Code |
Description |
|
DGT1S a> |
Weight transmitter on DIN bar, with 2 INPUTS and 2 OUTPUTS. Fitted with 5-key keypad and LED display. Multifunction weighing program. |
|
DGT1 a> |
Weight transmitter for DIN bar. 5-key keypad, LED display, real time clock, alibi memory, and multifunction weighing programme. |
|
DGT4 a> |
Transmitter for DIN bar with 4 channels, 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme. |
|
DGTQ a> |
Transmitter for panel mounting, with 2 IN and 2 OUT. 5-key keypad, LED display, and standard weighing programme. |
All the specifications and images can be subject to variations and upgrades without prior notice.
Golden Lotus Bending Beam loadcell – under weighing.lotusscale.com cert., FXC SERIES BENDING BEAM LOAD CELLS Dini Argeo load cell by Diniargeo made in Italy (EU type).
FXC SERIES BENDING BEAM LOAD CELLS Alu, stainless steel and alloy approved load cells, suitable for approved scales, or for weighing tanks and hoppers, with the aid of its accessories. Stainless steel compression load cells suitable for weighing, Digital version of compression load cells, 4000 divisions, Compression load cell for CE-M approved weighbridges, tanks, silos, etc. DiniArgeo Bending Beam loadcell Completely manufactured in steel, and fitted with selfaligned articulated joints, selfcentering plates and protection washer.
* Golden Lotus Loadcell products post at Lotusscale.com is under sale right by “Golden Lotus M.E.C” we distribute DiniArgeo Scales and DiniArgeo Loadcells in Asia, Southern Vietnam and can advise product solutions, products and services. Feel free to contact us: hsv@hoasenvang.com.vn / or Call us: 8428 3511 7799 (GMT +7).
About The Author
if a balance is incorrect, you should replace with a newer, instead of expecting to luck!